EasyCAP


STANDARDIZED CAP SETS

STANDARDIZED CAP SETS

We compiled easy-to-order complete cap sets for EEG from 19/21, 32/40 and 64/80 channels. The electrode arrangments are based on the international 10%-system. The chosen electrode positions ...

EASYCAP - SIGGI II

EASYCAP - SIGGI II

EASYCAP: EEG Recording Caps & Related Products EASYCAP GmbH, partner to Brain Products, manufactures a wide variety of EEG/ERP-Recording Caps for all age-groups as well as all related a...

CAPS FOR ADULTS

CAPS FOR ADULTS

encompass the sizes (= head circumference) 54, 56, 58, 60, 62. With two sizes, best choose 54 and 58, as third size choose 60.  ...

CAPS FOR CHILDREN

CAPS FOR CHILDREN

encompass the sizes 50 (5 years), 52 (approx. 6 years), 54 (9 years) and 56....

CAPS FOR INFANTS

CAPS FOR INFANTS

cover the sizes from 36 (newborn), 38, 40 (3 months), 42, 44 (7 months), 46, 48 (3 years) to 50.   With two cap sizes for every age range you will cover 70% of subjects, with ...

ADAPTORS

ADAPTORS

are necessary to mount the electrodes onto the cap or - with washers - onto the skin. When ordering caps, please always specify, where to mount the adaptors. Either choose a montage from our...

EEG ring electrodes (TP)

EEG ring electrodes (TP)

Sintered Silver-Silver Chloride (Ag/AgCl) ring electrodesElectrodes have to be ordered together with the specification of the correct termination and the leadwire length (from 100 to 200 cm)...

EEG ring electrodes (pin)

EEG ring electrodes (pin)

Sintered Silver-Silver Chloride (Ag/AgCl) ring electrodesElectrodes have to be ordered together with the specification of the correct termination and the leadwire length (from 100 to 200 cm)...

EAR-ELECTRODES

EAR-ELECTRODES

To attach the mini-clamps affords a little practice. As an alternative we therefore offer conventional ear clips too. For those, hat-shaped electrodes with flat rim are required (e.g. electr...

QUICK-CONNECT INTERFACES

QUICK-CONNECT INTERFACES

In order to connect and detach many electrodes quick and error free to any EEG amplifier we offer a common connector for up to 38 single electrodes....

INPUT BOX & ELECTRODE BOARD ADAPTOR

INPUT BOX & ELECTRODE BOARD ADAPTOR

Input box and electrode board adaptor are connected in no time by a 38-pin-Dsub-connector. The single channels of box and adaptor are numbered.   To connect an  to the BrainAmp amplifie...

CHEST BELTS AND CHIN BELTS

CHEST BELTS AND CHIN BELTS

may be used alternatively for fixing the caps. The GS systems are provided in the sizes S (age of elementary school), L (youths, adults) and XL (big adults). They are equipped with velcro ta...

ELECTROLYTES

ELECTROLYTES

This chloride-free gel supports the superior qualities of sintered electrodes: it is utmost stable and not influenced by sweat or body warmth. It allows lowest impedances for best signal q...

ELECTROLYTE PASTE FOR SKIN ELECTRODES

ELECTROLYTE PASTE FOR SKIN ELECTRODES

These two chlorided electrolyte pastes are suited to place single electrodes onto the head or - combinded with washers - onto the skin.Elefix is easier to remove, while EC2 is recommended fo...

DISINFECTION SOLUTION

DISINFECTION SOLUTION

Sekusept-PLUS, which is effective against (among others) Hepatitis B-Virus, HIV and TBC-bacteria, was tested together with the cap fabric and electrodes for tolerability. Since it is free of...

CONSUMABLES

CONSUMABLES

V30 Isopropylalcohol 70% (60 ml) For degreasing the skin...

CONSUMABLES

CONSUMABLES

V21 Skin Pure, tube 135 grams Gentle abrasive paste, for use with V14 or V15....

MISCELLANEOUS

MISCELLANEOUS

MHS-4025   Electrode holder                                                                                                           ...

MISCELLANEOUS

MISCELLANEOUS

 D01-58D01-58 Polysterene head large With pre-marked electrode positions: Fpz, Cz, Inion, T9, T10....

MISCELLANEOUS

MISCELLANEOUS

D01-56 Polysterene head medium With pre-marked electrode positions: Fpz, Cz, Inion, T9, T10.      The polysterene heads are meant for designing individual electrode arrangements or ju...

SINGLE LEADWIRE TERMINATIONS & ADAPTOR-CONVERTERS

SINGLE LEADWIRE TERMINATIONS & ADAPTOR-CONVERTERS

To make it possible to convert existing electrodes to other terminations we provide the 2mm-pins and 1,5mm safety sockets as single items. Each terminator comes with jacket and 1,5 cm adhesi...

OLDER PRODUCTS STILL AVAILABLE

OLDER PRODUCTS STILL AVAILABLE

Our former electrode types, Standard and Extra-flat, as well as their appropriate electrode adaptors and service is still available:...

SIGNAL GENERATOR / IMPEDANCE METER

SIGNAL GENERATOR / IMPEDANCE METER

Please click here for a detailed description of SIGGI II Signal Generator / Impedance Meter / Data Logger / Electrode Tester...

OTHER AG/AGCL SINTERED ELECTRODES IN VARIOUS SHAPES

OTHER AG/AGCL SINTERED ELECTRODES IN VARIOUS SHAPES

Further to our ring electrodes other electrodes in various shapes are available too. As the sensors are the same, these and ring electrodes can be used within the same recording...

EEG electrode E224A

EEG electrode E224A

Sintered Silver-Silver Chloride (Ag/AgCl) electrodes Skin electrode, Housing 16/8 mm...

EEG electrode E224N

EEG electrode E224N

Sintered Silver-Silver Chloride (Ag/AgCl) electrodesSkin electrode, Housing 13/8 mm...

EEG electrode E220A

EEG electrode E220A

Sintered Silver-Silver Chloride (Ag/AgCl) electrodesSkin electrode, Housing 13/4 mm  ...

EEG electrode E220N

EEG electrode E220N

Sintered Silver-Silver Chloride (Ag/AgCl) electrodesSkin electrode, Housing 7/4 mm...

EEG electrode E220X

EEG electrode E220X

Sintered Silver-Silver Chloride (Ag/AgCl) electrodesHat-shaped electrode...

EEG electrode E271

EEG electrode E271

Sintered Silver-Silver Chloride (Ag/AgCl) electrodesFlat electrode 4 mm...

EEG electrode E272

EEG electrode E272

Sintered Silver-Silver Chloride (Ag/AgCl) electrodesFlat electrode 8 mm...

EEG electrode E273

EEG electrode E273

Sintered Silver-Silver Chloride (Ag/AgCl) electrodesFlat electrode 12 mm...

SIGNAL GENERATOR / IMPEDANCE METER

SIGNAL GENERATOR / IMPEDANCE METER

Please click here for a detailed description of SIGGI II Signal Generator / Impedance Meter / Data Logger / Electrode Tester...

STANDARDIZED CAP SETS

STANDARDIZED CAP SETS

We compiled easy-to-order complete cap sets for EEG from 19/21, 32/40 and 64/80 channels. The electrode arrangments are based on the international 10%-system. The chosen electrode positions ...

EEG 10 20 system EaysCAP EC20#

EEG 10 20 system EaysCAP EC20#

EaysCAP EC20# Cap with 23 equidistant electrode positions (Int. 10/20-System) 26 Ag/AgCl sintered ring electrodes, number labeled 2 Ear-lobe electrodes Quick-connect interface Chest b...

EC40-#

EC40-#

Cap with 36 equidistant electrode positions (10%-System) 38 Ag/AgCl sintered ring electrodes, number labeled 2 Ear-lobe electrodes Quick-connect interface Chest belt set All necessary...

EC80-#

EC80-#

Cap with 74 equidistant electrode positions (10%-System) 78 Ag/AgCl sintered ring electrodes, number labeled 2 Ear-lobe electrodes 2 Quick-connect interfaces Chest belt set All necess...

ELECTRODE ARRANGEMENTS

ELECTRODE ARRANGEMENTS

The modular  system allows a multitude of different electrode arrangements for many electrophysiological problems. This booklet shows different electrode placements which have proven to b...

RECORDABLE AREA / 10%-SYSTEM

RECORDABLE AREA / 10%-SYSTEM

  10%-Electrode System and Electrode Position Nomenclature of the American Electroencephalographic Society   Montage No. 1   mostly equidistant, inter electrode distance ...

AMERICAN VS. GERMAN ELECTR. NOMENCLATURE

 AMERICAN VS. GERMAN ELECTR. NOMENCLATURE

  Differences between the 10%-Systems of the American Electroencephalographic Society and the Deutsche EEG-Gesellschaft   This graph shows the american electrode positions a...

INTERNATIONAL 10/20-SYSTEM

INTERNATIONAL 10/20-SYSTEM

This Montage is used in our standardized Ready-to-use Cap Set EC20.   23 electrode positions, mostly equidistant, inter electrode distance 53 to 74 mm (given a head circumference of 58 cm...

EXTENDED 10/20-SYSTEM WITH 30 CHANNELS

EXTENDED 10/20-SYSTEM WITH 30 CHANNELS

This electrode arrangement is the most-spread extension of the 10/20-system.   Unused channels of your amplifier can be used for EOG, ECG or other polygraphies....

SMALL EQUIDISTANT 29-CHANNEL-ARRANGMENT

 SMALL EQUIDISTANT 29-CHANNEL-ARRANGMENT

mostly equidistant, inter electrode distance 32 to 50 mm (given a head circumference of 58 cm).   These 29 electrode positions show the best possible equidistant selection of 10%-position...

LARGE EQUIDISTANT 32-CHANNEL-ARRANGEMENT

 LARGE EQUIDISTANT 32-CHANNEL-ARRANGEMENT

mostly equidistant, inter electrode distance 43 to 68 mm (given a head circumference of 58 cm).   This electrode arrangement encompasses the largest possible area, recordable from 32 equi...

LARGE EQUIDISTANT 34-CHANNEL-ARRANGEMENT

LARGE EQUIDISTANT 34-CHANNEL-ARRANGEMENT

mostly equidistant, inter electrode distance 43 to 68 mm (given a head circumference of 58 cm).   This electrode arrangement resembles a “15%-System”, covering the largest possible ar...

61-CHANNEL-ARRANGEMENT ("10%-SYSTEM")

 61-CHANNEL-ARRANGEMENT ("10%-SYSTEM")

mostly equidistant, inter electrode distance 28 to 38 mm (given a head circumference of 58 cm).   This classic 10%-system encompasses the same area as the 10/20-system....

74-CHANNEL-ARRANGEMENT

 74-CHANNEL-ARRANGEMENT

This Montage is used in our standardizedReady-to-use Cap Set EC80.   mostly equidistant, inter electrode distance 28 to 38 mm (given a head circumference of 58 cm).   This graph shows ...

128-CHANNEL-ARRANGEMENT

 128-CHANNEL-ARRANGEMENT

mostly equidistant, inter electrode distance 22 to 31 mm (given a head circumference of 58 cm).   The black electrode positions designate the 10%-system. The white ones are placed on the ...

SPHERICAL EQUIDISTANT 32-CH.-ARRANGEMENT

 SPHERICAL EQUIDISTANT 32-CH.-ARRANGEMENT

Inter electrode distance 53 ± 3 mm (given a head circumference of 58 cm).   This arrangement uses 32 equidistant positions out of the 124-channel montage by Gölz & Rösler, Marburg ...

EQUIDISTANT 61-CHANNEL-ARRANGEMENT

EQUIDISTANT 61-CHANNEL-ARRANGEMENT

Inter electrode distance 37 ± 3 mm (given a head circumference of 58 cm).   This montage was constructed out of triangles, which were measured on the threedimensional head surface and ar...

EQUIDISTANT 88-CHANNEL-ARRANGEMENT

EQUIDISTANT 88-CHANNEL-ARRANGEMENT

Inter electrode distance 29 ± 3 mm (given a head circumference of 58 cm).   Electrodes Nos. 75 and 88 are placed on the canthus, 81 on the inion....

SPHERICAL 124-CHANNEL-ARRANGEMENT

SPHERICAL 124-CHANNEL-ARRANGEMENT

Inter electrode distance 27 ± 3 mm (given a head circumference of 58 cm).   This montage (Gölz & Rösler, FB Psychologie, Philipps-Universität Marburg) is characterized by near-to-...

BESA 32-CH.-ARR. FOR EPILEPSY DIAGNOSTICS

 BESA 32-CH.-ARR. FOR EPILEPSY DIAGNOSTICS

This electrode arrangement is recommended in the BESA and FOCUS manuals by Prof. Scherg, Heidelberg, for use in epilepsy diagnostics and for dipole analysis.   More information about the ...

29-CH.-ARR. FOR LANGUAGE RESEARCH

29-CH.-ARR. FOR LANGUAGE RESEARCH

This electrode arrangement sometimes is used in language research (e.g. MPI for Psycholinguistics, Nijmegen). The grey electrodes are standard 10% positions.   The black electrodes are pl...

2X64-CHANNEL-KOMBI-MONTAGE

 2X64-CHANNEL-KOMBI-MONTAGE

One possibility to apply the modular -concept is to use different arrangements within one cap.   The graphic shows as an example an arrangement by Dr. Th. Weiss, Dept. of Psychology,...

EEG SMARTING

EEG SMARTING

mBrainTrain started with a desire to make the first truly mobile research EEG device. Teaming with EasyCap brought to light SMARTING that represents exactly this: fully mobile EEG on a Smar...